2014 Gillig LOW Floor recalls

Source: NHTSA data as of September 22, 2026. Last refreshed Sep 23, 2026, 2:43 AM UTC.

23 recalls found in NHTSA data as of September 22, 2026

For the 2014 Gillig LOW Floor. These apply to the model and year, not to one particular vehicle: check your VIN to see whether yours is included and whether it has been repaired.

Has your Gillig been repaired?

Recalls here come from NHTSA’s records for the model and year. Not every vehicle of a model is included in every recall, and this site can’t see whether a repair has been done. Only a VIN lookup can tell you that.

NHTSA’s VIN search doesn’t show recalls that were already repaired, recalls more than 15 years old, or some small manufacturers’ recalls. A Gillig dealer can also check your VIN. Recall repairs are free.

2014 Gillig LOW Floor recalls, newest first

April 25, 2022NHTSA 22V276000592 vehicles potentially affected

Electrical system › 12V/24V/48V battery

Summary
Gillig, LLC (Gillig) is recalling certain 2014-2021 Low Floor transit buses. The rear-mounted ultracapacitors may allow the engine to be started when the master battery disconnect switch is in the "OFF" position.
Consequence
The engine may be started unexpectedly, increasing the risk of injury to anyone nearby the engine compartment during maintenance operations.
Remedy
Dealers will update the software for the buses equipped with the Vanner Ultracapacitor system, and conduct a hard rewire for the buses equipped with the KBI system, free of charge. Owner notification letters were mailed on June 22, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 for 1-800-735-1500.

This recall on nhtsa.gov

July 2, 2020NHTSA 20V392000531 vehicles potentially affected

Steering › Hydraulic power assist › Pump

Summary
Gillig, LLC. (Gillig) is recalling certain 2013-2020 hybrid and all-electric Low Floor buses equipped with a steering system that uses a high-voltage electric motor and hydraulic pump assembly to provide power steering assist. The shaft coupling between the motor and pump may fail and cause a loss of hydraulic power steering assist.
Consequence
A loss of power steering assist may increase the risk of crash.
Remedy
Gillig will notify owners, and dealers will replace the motor-pump assemblies, free of charge. The recall began August 13, 2020. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

March 25, 2020NHTSA 20V1790008,224 vehicles potentially affected

Electrical system › Wiring › Fuses and circuit breakers

Summary
Gillig LLC (Gillig) is recalling certain 2012-2020 Low Floor buses. The circuit breaker ratings on the DEF Line Heater circuit and the Aftertreatment-Ignition circuit may be higher than the rating for the wire and connector.
Consequence
With the improper circuit breaker rating, an electrical short in either of these circuits may increase the risk of a fire.
Remedy
Gillig will notify owners, and dealers will replace the circuit breakers, free of charge. The recall began April 24, 2020. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

This recall on nhtsa.gov

March 8, 2019NHTSA 19V193000965 vehicles potentially affected

Exterior lighting › Headlights

Summary
Gillig LLC (Gillig) is recalling certain 2014-2019 Low Floor buses. Uncovered electrical terminals in the headlight power circuit may short circuit to ground, causing a loss of headlights.
Consequence
A loss of headlights can reduce the driver's ability to see, increasing the risk of a crash.
Remedy
Gillig has notified owners, and dealers will install new back covers on the headlight buckets, free of charge. The recall began April 1, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

This recall on nhtsa.gov

November 9, 2018NHTSA 18V7890004,469 vehicles potentially affected

Parking brake › Conventional › Air

Summary
Gillig LLC (Gillig) is recalling certain 2013-2018 Gillig Low Floor transit buses equipped with disk brakes. The spring cage bolts on the air brakes may not be sufficiently tightened, reducing the effectiveness of the parking brake.
Consequence
Loose cage bolts may result in the bus rolling away when in the park position or a loss of braking ability if the service brake air pressure is lost while moving. Either condition may increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will tighten the spring cage bolts, free of charge. The recall began December 10, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
Components
Parking brake › Conventional › Air; Service brakes, air

This recall on nhtsa.gov

August 9, 2018NHTSA 18V511000178 vehicles potentially affected

Exterior lighting › Turn signal

Summary
Gillig LLC (Gillig) is recalling certain 2012-2018 Gillig Low Floor vehicles. The front and rear turn signals on these vehicles may flash at different rates, potentially confusing other drivers of the vehicle's intention. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence
The mismatched flashing may confuse other drivers, increasing the risk of a crash.
Remedy
Gillig will notify the owner of the buses, and dealers will reprogram the turn signals with new software, free of charge. The recall began August 30, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

This recall on nhtsa.gov

June 20, 2018NHTSA 18V41800025,579 vehicles potentially affected

Exterior lighting › Turn signal › Flasher unit

Summary
Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence
The reduced visibility of the turn signals can increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
Components
Exterior lighting › Turn signal › Flasher unit; Exterior lighting › Turn signal

This recall on nhtsa.gov

September 8, 2017NHTSA 17V559000108 vehicles potentially affected

Steering › Electric power assist system

Summary
Gillig LLC (Gillig) is recalling certain 2013-2016 Hybrid and all Electric Low Floor buses with electro-hydraulic power steering assist. The coupler between the high-voltage electric motor and hydraulic steering pump shafts may fail, resulting in a loss of power steering assist.
Consequence
A loss of power steering assist will cause the need for increased steering effort, increasing the risk of a crash.
Remedy
Gillig will notify owners, and dealers will replace the steering motor-pump assemblies, free of charge. The recall began on October 24, 2017. Owners may contact Gillig customer service at 1-800-735-1500.
Components
Steering › Electric power assist system; Steering › Hydraulic power assist system

This recall on nhtsa.gov

February 24, 2017NHTSA 17V11900017,056 vehicles potentially affected

Exterior lighting › Turn signal

Summary
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence
The reduced visibility of the turn signals may increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

This recall on nhtsa.gov

September 14, 2016NHTSA 16V66200034 vehicles potentially affected

Service brakes, air › Supply › Hoses, lines/piping, and fittings

Summary
Gillig LLC (Gillig) is recalling certain model year 2014-2016 Gillig 29-foot Low Floor transit buses manufactured November 20, 2014, to February 11, 2016. These buses, equipped with disc brakes, have rear brake hoses that can rub chassis components and fray.
Consequence
A frayed hose may leak air, causing the rear brake(s) to lock up unexpectedly, or fail to operate when the brakes are applied. Either scenario increases the risk of a crash.
Remedy
Gillig will provide fleets new rear brake hoses, fittings, clamps, and hardware along with instructions on how to reorient the hoses using the new fittings, and reimburse them for their labor, free of charge. The recall began on September 29, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

June 21, 2016NHTSA 16V451000112 vehicles potentially affected

Exterior lighting › Brake lights

Summary
Gillig LLC (Gillig) is recalling certain model year 2012-2016 Lowfloor diesel-electric hybrid vehicles manufactured March 6, 2012, to June 7, 2016. The affected vehicles are equipped with stop lamp activation that may inadvertently flash the rear brake lights. As such, these vehicles do not comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) No. 108, "Lamps, Reflective Devices, and Assoc. Equipment."
Consequence
Flashing brake lights may cause confusion to other drivers, increasing the risk of a crash.
Remedy
Gillig will notify owners, and dealers will install a new software update, free of charge. The recall began on July 2016. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

January 13, 2016NHTSA 16V0110006,734 vehicles potentially affected

Seats

Summary
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.
Consequence
If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.
Remedy
Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

December 30, 2015NHTSA 15V88800016 vehicles potentially affected

Service brakes, hydraulic

Summary
Gillig LLC (Gillig) is recalling certain model year 2014-2015 Low Floor vehicles manufactured November 20, 2014, to June 2, 2015. The affected vehicles may be equipped with front brake chambers with an incorrect drain hole orientation. This can allow water to build up within the brake chamber, causing corrosion, deterioration, and reduce braking ability.
Consequence
Corrosion, part deterioration, or frozen water in the brake chamber may reduce braking ability, increasing the risk of a crash.
Remedy
Gillig will notify owners and the brake chambers will be replaced free of charge. The recall began on March 1, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

July 1, 2015NHTSA 15V4200006,971 vehicles potentially affected

Electrical system › Wiring › Front underhood

Summary
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.
Consequence
If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.
Remedy
Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

May 19, 2015NHTSA 15V295000263 vehicles potentially affected

Exterior lighting › Tail lights

Summary
Gillig LLC (Gillig) is recalling certain model year 2014-2015 Low Floor vehicles manufactured September 1, 2014, to April 30, 2015. The affected vehicles may have a taillight bracket that is inadequately bonded to the bus body.
Consequence
If the bracket is inadequately bonded, it may detach from the body, preventing the stop and turn lights from being visible to following vehicles, increasing the risk of a crash.
Remedy
Gillig has notified owners. Gillig will inspect the taillight brackets to verify that they are properly bonded to the body. Brackets that are not properly bonded will be removed and properly bonded to the vehicle, free of charge. The recall began on June 12, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

May 5, 2015NHTSA 15V2620001,101 vehicles potentially affected

Engine and engine cooling › Engine

Summary
Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.
Consequence
If engine oil comes into contact with a hot surface, there is an increased risk of a fire.
Remedy
Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 2, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

April 14, 2015NHTSA 15V219000623 vehicles potentially affected

Service brakes, air › Disc

Summary
Gillig LLC (Gillig) is recalling certain model year 2013-2015 Low Floor transit buses manufactured July 8, 2013, to February 7, 2015 and equipped with disc brakes. The front left and right brake air hoses that connect to the brake chamber may touch and rub against the air bag suspension towers.
Consequence
If the front brake hoses rub the air bag suspension tower, a hole may develop and the resulting air leak may reduce the brake air pressure, lengthening the distance needed to stop the transit bus and increasing the risk of a crash.
Remedy
Gillig has notified owners, and dealers will replace the brake hoses with shorter ones that will not contact the suspension tower, free of charge. The recall began on April 28, 2015. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

September 10, 2014NHTSA 14V54700090 vehicles potentially affected

Service brakes, air

Summary
Gillig LLC (Gillig) is recalling certain model year 2014 Lowfloor transit buses manufactured January 2, 2014, to March 6, 2014. In the affected vehicles, the air brake system supply lines from the primary and secondary air tanks to the brake valves may have been crossed at the bulkhead during assembly. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard No. 121, "Air Brake Systems."
Consequence
If the primary and secondary air brake supply lines from the tanks to the brake valve are crossed and the vehicle loses pressure in the primary tank, the vehicle service brake system performance may be reduced. In the case of a total loss of primary tank air pressure, the service brake system will not function. If the service brake system does not function or performance is reduced, an application of the brake pedal by the vehicle operator may not slow or stop the vehicle as expected, increasing the risk of a crash.
Remedy
Gillig will notify owners, and dealers will correct the installation of the primary and secondary brake supply lines, free of charge. The recall began on October 17, 2014. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

August 28, 2014NHTSA 14V521000231 vehicles potentially affected

Fuel system, diesel

Summary
Gillig LLC (Gillig) is recalling certain model year 2014 Low Floor transit buses manufactured from May 23, 2014, through August 1, 2014. The Cummins ISB or ISL engines in these vehicles may have been equipped with Fleetguard UFF-XT fuel filters, part number FF63009, whose filter shell may separate from the fuel filter nut plate causing the engine to stall without warning.
Consequence
If the engine stalls unexpectedly there is an increased risk of a crash.
Remedy
Cummins will notify owners on behalf of Gillig, and Cummins service centers will replace the fuel filter, free of charge. The recall began on September 16, 2014. Owners may contact Gillig at 1-510-785-1500 or Cummins customer service at 1-812-377-3713.

This recall on nhtsa.gov

July 28, 2014NHTSA 14V459000252 vehicles potentially affected

Service brakes, air › Disc

Summary
Gillig, LLC (Gillig) is recalling certain model year 2013-2014 Low Floor transit buses manufactured July 25, 2013, to June 17, 2014. The affected vehicles may have been produced without a quick release valve for the rear brakes on buses built with rear disc brakes. As such, these vehicles fail to comply with Federal Motor Vehicle Safety Standard No. 121, "Air Brake Systems."
Consequence
If the bus's anti-lock brake system was non-functioning and the bus experienced a significant braking event that when combined with the road conditions may lock the rear brakes, then a delay in brake release timing could result in a lock up of the rear wheels, increasing the risk of crash.
Remedy
Gillig will notify owners, and dealers will install a quick release valve, free of charge. The recall began on September 15, 2014. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

June 23, 2014NHTSA 14V358000648 vehicles potentially affected

Engine and engine cooling › Engine

Summary
Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Consequence
If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Remedy
Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

April 25, 2014NHTSA 14V2220002,274 vehicles potentially affected

Electrical system › Wiring

Summary
Gillig LLC (Gillig) is recalling certain model year 2012-2014 Lowfloor transit buses manufactured October 15, 2012, through March 26, 2014, and equipped with electrical harnesses with overmolded J1939 connectors and non-insulated drain wires. The harnesses do not have heat shrink tubing on the drain wire and the overmold may not have sufficient resistance to water or corrosive chemical entry to the connectors.
Consequence
If the terminals corrode, there may be an intermittent electrical connection and possibly cause disruption or loss of the J1939 communication, resulting in interruptions of the engine, transmission, ABS and body controllers, increasing the risk of a crash.
Remedy
Gillig will notify owners, and dealers will replace the overmold connector, and install heat shrink tubing on the connector/cable junction, free of charge. The recall began in June 2014. Owners may contact Gillig customer service at 1-800-735-1500.

This recall on nhtsa.gov

February 27, 2014NHTSA 14V084000643 vehicles potentially affected

Engine and engine cooling › Engine

Summary
Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.
Consequence
The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.
Remedy
Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1-510-785-1500 or Cummins Inc. at 1-800-343-7357.

This recall on nhtsa.gov

Owner complaints

Owners have filed 1 complaint about the 2014 Gillig LOW Floor with NHTSA. Complaints are unverified reports from the public; NHTSA uses them to decide what to investigate.

Crashes reported
0
Fires reported
0
Injuries reported
0
Deaths reported
0

Most complained-about components

  1. Electrical system1
  2. Engine1

Other Gillig LOW Floor years

Other 2014 Gillig models

Most recalled 2014 vehicles

  1. 2014 Thomas Built Buses SAF-T-Liner HDX (30 recalls)
  2. 2014 Spartan Gladiator (28 recalls)
  3. 2014 Blue Bird All American (26 recalls)
  4. 2014 Gillig LOW Floor (23 recalls)
  5. 2014 Blue Bird Vision (22 recalls)
All of 2014’s most recalled vehicles

Questions

Does the 2014 Gillig LOW Floor have any recalls?
23 recalls found in NHTSA data as of September 22, 2026, covering: electrical system, steering, exterior lighting, parking brake, service brakes, air, seats. Recalls apply to the model and year; whether a particular vehicle is included, and whether it has been repaired, depends on its VIN.
How do I check if my 2014 Gillig LOW Floor recall has been fixed?
Enter your 17-character VIN at nhtsa.gov/recalls, or ask a Gillig dealer. Recall repairs are free. NHTSA's VIN search doesn't list recalls that were already repaired.
How many complaints have owners filed about the 2014 Gillig LOW Floor?
1 complaint filed with NHTSA. Complaints are unverified reports from the public that NHTSA uses to decide what to investigate.